Tuz purkash testi ishonchlimi?

Jan 24, 2022

Red Rust Corrosion

Salt spray test has been recognized for ranking the performance levels of coating systems. Yet, there is little correlation between results from standard salt spray tests and real-life anti-corrosion performance. In particular, it will not be able to give accurate assessment for galvanized coating because the continual wetness during the salt spray test does not allow this passive oxide and carbonate layer to develop, and this adherent layer protects the zinc from corrosion meanwhile zinc protects the substrate steel from erosion. When coated material is evaluated by the salt spray test, but it does not have ultraviolet light which will cause deterioration for paints and primers. Therefore, using salt spray test results to guide the selection of protective coatings for steel is quite a serious problem in the engineering field. Despite the well understood limitations of the test, many project designers use the salt spray test result as a guideline to choose their favorite coatings. For decades, this test has generated misleading information about coating performance and its results still feature prominently in the marketing materials of products that yield more favorable outcomes than in practical world. This article is meant for giving some insight into the limitations of this type of accelerated testing. 

What is salt spray test? 


Salt Spray Test

There are two types of salt spray tests in common use, neutral and acetic acid, but neither of these does what we want in a test, which is to replicate nature on an accelerated time basis. It's also called salt fog test which is standardized and popular corrosion test solution, and it's used to check corrosion resistance of materials and surface coatings. Usually, the materials to be tested are metallic and finished with a surface coating which is intended to provide a degree of corrosion protection to the underlying metal. It is an accelerated corrosion test that produces a corrosive attack to coated samples for assessing the effectiveness of the protective coating. The appearance of corrosion is evaluated after a certain period of time, and test duration depends on the corrosion resistance of the coating. Generally, the more corrosion resistant the coating is, the longer the period of testing before the appearance of corrosion or rust. The salt spray test is one of the most widespread and long-established corrosion tests, and ASTM B117 was the first internationally recognized standard which was published in 1939. The other important relevant standards are ISO 9227, JIS Z 2371 and ASTM G85. 

Let's take a look at the testing process first. The salt spray procedure involves the spraying of a salt solution with 5 percent salt (sodium chloride) onto the samples, and the test is done inside a temperature-controlled chamber. The temperature within the chamber is maintained at a constant level, and the samples are constantly subject to the saltwater spray, and the testing procedure of ASTM B117 is listed below:  
√  Placing wooden in the chamber  
√  Namunalarni yog'och tokchaga kichik egilish burchagi bilan joylashtiring
√  Suv omboridan purkagichlarga pompalanadigan musluk suvida 5 foiz NaCl
√  Namlangan siqilgan havo bilan nozullarda aralashtirilgan eritma
√  Siqilgan havo NaCl eritmasini nozullarda tumanga aylantiradi
√  Isitgichlar idishni haroratini 95 daraja F ushlab turadi
√ Sinov davomiyligi 24 soatdan 1000 soatgacha bo'lishi mumkin va namunalar tez-tez aylantirilib turiladi, shunda barcha namunalar tuz purkagichli tumanga imkon qadar bir xilda ta'sir qiladi.

Tuz purkash sinovi metall{0}}qoplamali po'lat plitalarni sinash uchun ishlatilsa, korroziyaga qarshi ko'rsatkichlar quyidagi usullar bilan baholanadi:
√  Nr. po'latning zanglashi birinchi marta aniq bo'lgunga qadar soat
√  Nr. soatlab sirt maydonining 5 foizi zanglagangacha
√  Nr. of hours until 10 percent of the surface area is rusted 

Bo'yoqqa dastlabki ishlov berish, bo'yoq astarlari yoki oxirgi qoplamalar samaradorligini baholash quyidagi mezonlar bo'yicha o'lchanadi:
√  Sinov kamerasida 250, 500, 750 soat davomida ta'sir qilgandan so'ng, bo'yoqning chizilgan chizig'i bo'ylab yoki kesilgan chetida kesilgan bo'yoqning kengligini o'lchash
√  250, 500, 750 soat ichida bo'yalgan po'lat panelning yuzalarida paydo bo'lgan bo'yoq pufakchalari miqdorini o'lchash.

Why is salt spray test misleading? 

As you might be aware that salt spray test (B117) does not involve any exposure to ultraviolet light, paint fading and chalking. Though G85 has several modifications involving cyclic additions of acid and SO2, but it still can't correlate with outdoor performance in chloride atmosphere. There are three most important reasons for the salt spray test not correlating with most real-world exposure conditions.
√  The surface of the test samples is constantly wet, which does not happen in a real environment. 
√  The chamber temperature is constantly at 95 degree F, which increases water, oxygen and ion transport compared to the real atmosphere. 
√  The chloride content is at a very high level of 5 percent , preventing zinc from forming a passive film.  

Of course, it's not fair to say that salt spray does not have any value because it does provide a quantitative analysis of anti-corrosion performance, and therefore this test is widely used in powder coating and painting industry to verify the coating material's quality. For example, if the normal performance in the salt spray test is 750 hours before the onset of corrosion, it is a quick way to determine if there are any major production problems affecting the product quality. The test may not conclude that the product quality is acceptable, but if the performance in this test is substandard, the outdoor performance might also not be as good as expected to be. Not surprisingly, ISO 9227 recommends that salt spray tests are suitable only as quality control tests.

In short, salt spray test is not an accurate way of evaluation of corrosion resistance primarily because the salt spray destroys the mechanism that galvanized finish protects the steel by providing a barrier, and this barrier is also an important electrolytic protection. Due to this reason, the test result might lead to a false conclusion on how the galvanized finish will perform, which renders the test meaningless. No wonder, this test is now largely abandoned even by the automotive industry. 

Unfortunately, this test is still rather popular. Despite ISO 9227 clearly states that "There is seldom a direct relation between resistance to the action of salt spray and resistance to corrosion in other media, because several factors influencing the progress of corrosion, such as the formation of protective films, vary greatly with the conditions encountered." If the project designer is knowledgeable about what the salt spray test really means, he can then understand its limitations and use the results in a judicious manner.

Haqiqiy muhitda korroziyaga nima sabab bo'ladi?

The most common metallic corrosion is atmospheric. If metals like steel, copper, magnesium and aluminum are exposed to the atmosphere, they react with free-flowing air and moisture to develop oxides. The atmospheric corrosion depends on five main factors: 
√  Harorat
√  Namlik
√  Yomg'ir
√  Sulfur dioxide, it's mainly formed by pollution concentration in the air
√  Air salinity. 

Ushbu omillarning hech birini korroziyaga asosiy hissa qo'shuvchi sifatida ajratib bo'lmaydi. Ushbu metallar bo'yicha keng qamrovli tadqiqotlar o'tkazildi va ularning har biri uchun bashorat qilinadigan korroziya tezligi aniq hisoblab chiqilgan. Quyidagi mikro muhitlarda uglerodli po'latning umumiy korroziya darajasi ushbu korroziya tezligidan ancha yuqori bo'lishi mumkin.
√  Tuproqda po'lat atmosfera ta'sirida bo'lganidan farqli o'laroq, bir qator korroziv kuchlarga duchor bo'ladi. Faqat Shimoliy Amerikada 200 dan ortiq turli tuproq turlari aniqlangan va korroziya tezligi to'rtta asosiy omil bilan belgilanadi: tuproq harorati, namlik, pH darajasi va xloridlar. Agar ulardan biri bo'lmasa, korroziya reaktsiyasi to'xtaydi yoki juda sekin davom etadi. Chelik kislotali muhitda tez korroziyaga uchraydi va ishqoriylik ortishi bilan sekin yoki umuman korroziyaga uchraydi. Tuproqdagi po'latning korroziya darajasi qulay sharoitlarda yiliga 0,2 mikrondan kam bo'lib, juda agressiv tuproqlarda yiliga 20 mikron yoki undan ko'p bo'lishi mumkin.

Corrosion Marine Environment

√  Marine or water, a less common environment for metal is submerged in or exposed to water. Moisture is highly corrosive to most metals including steel, aluminum, and zinc. There are many different types of water (pure water, natural fresh water, drinking water, and seawater, and each has different mechanisms that determine the corrosion rate. The parameters that affect corrosion of metals in water include pH level, oxygen content, water temperature, agitation, the presence of inhibitors, and tide conditions. Onshore areas of marine corrosion include docks, harbors, naval yards, where sacrificial anodes providing cathodic protection may be employed, as well as protective coatings such as marine paints and galvanization. Offshore oil and gas platforms are exposed to particularly aggressive corrosion from sea salt spray and immersion.

Corrosion Above Ground

Above ground,there are five important factors that are essential to atmospheric corrosion: moisture (dew condensation), temperature, humidity, aerosol particle deposition and pollutants. For instance, every 50 degree F (10 degree ) increase in the temperature can double corrosion activity. Another interesting phenomenon is that salt-rich environment and aerosols tend to have high levels of humidity. 

Atmosfera korroziyasini tushunish juda muhim, chunki bu turdagi shikastlanish korroziya shikastlanishining har xil turlari orasida eng ko'p tarqalgan va u tashqi va ichki qurilmalarga ta'sir qiladi, masalan, kommunal xizmatlar,infratuzilmalar, quyosh energiyasi loyihalari, Telekommunikatsiya loyihalari, qishloq xo'jaligi loyihalari, transport vositalari,dok qurilishiva turar-joy inshootlari.



So'rov yuborish